Res. Biomed. Eng. (Online) ; 32(2): 105-110, Apr.-June 2016. tab, graf
Article in English | LILACS | ID: biblio-829475

ABSTRACT

Abstract Introduction: The dental radiology represents about 20% of human exposure to radiation in radio diagnostic. Although the doses practiced in intraoral dentistry are considered low, they should not be ignored due to the volume of the performed procedures. This study presents the radiation protection conditions for intraoral radiology in Curitiba - PR. Methods Data was collected through a quantitative field research of a descriptive nature during the period between September of 2013 and December of 2014. The survey sample consisted of 97 dentists and 130 intraoral equipments. The data related to the equipments was collected using structured questions and quality control evaluations. The evaluations of the entrance skin dose, the size of the radiation field and the total filtration were performed with dosimetry kits provided and evaluated by IRD/CNEN. The exposure time and voltage were measured using noninvasive detectors. The occupational dose was verified by thermoluminescent dosimeters. The existence of personal protection equipment, the type of image processing and knowledge of dentists about radiation protection were verified through the application of a questionnaire. Results Among the survey's results, it is important to emphasize that 90% of the evaluated equipments do not meet all the requirements of the Brazilian radiation protection standards. Conclusion The lack of knowledge about radiation protection, the poor operating conditions of the equipments, and the image processing through visual method are mainly responsible for the unnecessary exposure of patients to ionizing radiation.

2.
Res. Biomed. Eng. (Online) ; 31(1): 78-81, Jan-Mar/2015. graf
Article in English | LILACS | ID: biblio-829417

ABSTRACT

Introduction Intraoral film processing can be performed manually using chambers manufactured from opaque material to prevent light from entering and consequently blurring images. The aim of this study was to evaluate whether portable darkrooms used in offices, clinics and educational institutions prevent the entry of light during the processing of intraoral films. Methods To this end, tests were carried out and images were analyzed by measuring the optical base-plus-fog densities (ODs) upon imaging. Results Review of the OD measurements revealed that in 70.7% of the evaluated manual portable revelation cameras, the base-plus-veil density of intraoral films was not in accord with that of the protocol reference. Discussion The results of this work can be used to identify chambers that are commonly exposed to light from fluorescent lamps and solar lighting.

3.
Radiol. bras ; 42(5): 309-313, set.-out. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-530179

ABSTRACT

OBJETIVO: O presente estudo consistiu em investigar a influência da radiação ionizante por raios X e raios gama sobre a estabilidade molecular de diversos meios de contraste radiológicos utilizados em exames de diagnóstico por imagem, por meio da espectroscopia de ressonância magnética nuclear de ÕH e 13C. MATERIAIS E MÉTODOS: Oito diferentes meios de contraste iodados (três iônicos e cinco não iônicos) foram expostos à radiação por raios X e raios gama. Em seguida, espectros de ressonância magnética nuclear de ÕH e 13C{ÕH} foram coletados. RESULTADOS: Os espectros de ressonância magnética nuclear de 13C{ÕH} de ambos os meios de contraste iônicos e não iônicos irradiados por raios X ou raios gama mostraram que não houve alterações na composição química desses contrastes. CONCLUSÃO: Não há problemas em armazenar as amostras nas salas, ou próximo aos equipamentos em que são realizados os exames. Enfatiza-se que a radiação recebida pelas amostras durante os ensaios foi direta, enquanto em uma sala de exames de radiodiagnóstico a radiação é indireta e, portanto, os níveis de radiações nestes casos são bastante inferiores àqueles empregados neste estudo.


OBJECTIVE: The purpose of the present study was to investigate the influence of ionizing radiation from x-rays and gamma rays on the molecular structure stability of several radiologic contrast media employed in diagnostic imaging by means of ÕH and 13C nuclear magnetic resonance spectroscopy. MATERIALS AND METHODS: Eight different types of iodinated contrast media (three ionic and five non-ionic) were exposed to x-rays and gamma rays irradiation. Subsequently, the ÕH and 13C{ÕH} nuclear magnetic resonance spectra of these contrast media were collected. RESULTS: The ÕH and 13C{ÕH} nuclear magnetic resonance spectra of both ionic and non-ionic contrast media irradiated by x-rays or gamma rays demonstrated the absence of any alteration of the contrast media chemical composition. CONCLUSION: There is no problem in keeping contrast media inside examination rooms or close to radiological equipment. It is important to mention that, during the tests, the samples were directly irradiated, while in a radiology examination room, the irradiation is not direct and, therefore, radiation levels in these cases are much lower than those employed in the present study.


Subject(s)
Humans , Diagnostic Imaging/methods , Gamma Rays , Magnetic Resonance Spectroscopy , Contrast Media/analysis , Contrast Media/radiation effects , Radiation, Ionizing , X-Rays
4.
Radiol. bras ; 39(2): 123-126, mar.-abr. 2006. ilus, tab
Article in Portuguese | LILACS | ID: lil-430815

ABSTRACT

OBJETIVO: Avaliar a dose efetiva recebida pelos trabalhadores envolvidos na realização de procedimentos de hemodinâmica, de forma a estabelecer parâmetros comparativos entre os dados obtidos com uma câmara de ionização e pelos dosímetros usados para monitoração individual. MATERIAIS E MÉTODOS: A avaliação foi desenvolvida em um serviço de hemodinâmica, sendo que os testes constaram da medida do taxa de kerma no ar no ambiente real de trabalho, na posição ocupada por médicos e enfermeiros, com e sem a utilização de barreira plumbífera de proteção. Foi levado em consideração o número de exames realizados no serviço e foram selecionados as projeções e parâmetros radiográficos mais utilizados. Para a estimativa da dose efetiva foram utilizados fatores de conversão encontrados na literatura. RESULTADOS: Os valores encontrados em dose efetiva e de dosimetria são consistentes. Observou-se, ainda, que o uso da barreira protetora plumbífera reduz em até 97 por cento a dose recebida pelo profissional, devendo esta ser utilizada na rotina de exames. CONCLUSAO: Os valores apresentados são representativos, não podendo ser assumidos como reprodução das condições de monitoração individual, mas são válidos para comparações e orientação na otimização das doses.


Subject(s)
Humans , Allied Health Personnel , Occupational Exposure , Hemodynamics , Dosimetry , Radiation Dosage , Hemodynamics/radiation effects
5.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.461-462, tab.
Monography in Portuguese | LILACS | ID: lil-233819

ABSTRACT

As mais diversas especialidades médicas obtém preciosos benefícios como resultado de aplicações de radiações ionizantes, seja para fins terapêuticos, diagnósticos ou em pesquisa. Pesquisadores e engenheiros desdobram-se na busca de aperfeiçoamentos e novas aplicações. Cabe a estes quantificar de maneira válida as implicações resultantes desta utilização. Índices capazes de expressar a situação existente em um dado momento são muitos, e a sistematização da informação em torno desses índices pode contribuir muito à disseminação da prática da proteção radiológica.


Subject(s)
Quality Indicators, Health Care , Health Status Indicators , Professional Practice , Radiation Protection , Quality Control , Indicators of Health Services/methods , Indicators of Health Services/standards
6.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.383-384, graf.
Monography in Portuguese | LILACS | ID: lil-236405

ABSTRACT

Este trabalho apresenta uma avaliação da dose de entrada à superfície em pacientes submetidos a exames reais, proporcionada pela técnica radiográfica presente em 10 salas da cidade de Curitiba - PR no período de 12/95 a 04/96. Objetiva delinear as bases para estudos mais extensos, de nível local ou regional. É resultado da cooperação entre a SESA-PR e CIDRA-USP no desenvolvimento de pesquisa e capacitação técnica em saúde pública.


This work presents an evaluation of entrance skin dose in patients submitted at real examinations, arising from present radiographic technic in 1 O rooms of county of Curitiba - PR, between 12/95 and 04/96. Objectify outline the basis for extensive studies, on local or regional levei. Is the result of cooperation between the SESA-PR and CIDRA-USP in development of research and technical capacitation on public health.


Subject(s)
Radiography , Radiation Dosage , Radiography/trends , Urography/radiation effects , Abdomen/radiation effects , Public Health , Ancillary Services, Hospital , Thorax/radiation effects